master's thesis
Testing of Hydraulic Pumps in Thermoelektric Power Plant – Heating Plant HEP Osijek

Kruno Marijanović (2017)
Josip Juraj Strossmayer University of Osijek
Faculty of agriculture
DEPARTMENT FOR AGRICULTURAL TECHNICS
Metadata
TitleIspitivanje vibracija hidrauličkih crpki u termoelektrani-toplani HEP Osijek
AuthorKruno Marijanović
Mentor(s)Pavo Baličević (thesis advisor)
Abstract
Mjerenje brzine vibracija cirkulacijskih crpki provedeno je u termoelektrani-toplani HEP Osijek. Jedna od metoda održavanja po stanju je kontrola vibracija. Mjerenje brzina vibracija obavljeno je putem SKF mjernog sustava kroz četiri vremenska razdoblja. Prema ISO 10861-1 normi, brzine vibracija ispod 7,10 mm/s su dobre ili zadovoljavajuće. Izračunavanjem amplitude brzine AV i srednje efektivne vrijednosti brzine titranja VRMS, došlo se do zaključka da se vibracije na sve tri cirkulacijske crpke nalaze u dobrom ili zadovoljavajućem području. Izračunom Av vrijednosti i VRMS srednje vrijednosti prikazane su dvije krivulje za mjerno mjesto CPV1-1H. Prva predstavlja izgled vala dobiven spajanjem četiri maksimalne AV vrijednosti za svaku točku, dok druga prikazuje amplitudu brzine AV i VRMS srednje efektivne vrijednosti brzine titranja iz koje se vidi „teorijski“ izgled vala za Mjerno mjesto CPV1-1H
Keywordscirculation pumps alanyses and measuring vibrations
Parallel title (English)Testing of Hydraulic Pumps in Thermoelektric Power Plant – Heating Plant HEP Osijek
Committee MembersDrago Kraljević (committee chairperson)
Željko Barač (committee member)
GranterJosip Juraj Strossmayer University of Osijek
Faculty of agriculture
Lower level organizational unitsDEPARTMENT FOR AGRICULTURAL TECHNICS
PlaceOsijek
StateCroatia
Scientific field, discipline, subdisciplineBIOTECHNICAL SCIENCES
Agronomy
Agricultural Engineering and Technology
Study programme typeuniversity
Study levelgraduate
Study programmeMechanization
Academic title abbreviationmag. ing. agr.
Genremaster's thesis
Language Croatian
Defense date2017-05-29
Parallel abstract (English)
The measuring of vibration velocity for circulation pumps has been conducted in the thermal power plant HEP Osijek. Monitoring of the vibrations in one of maintenance methods. Vibration velocity measurements have been taken in four different time periods using SKF measuring system. According to ISO 10816-1 standard, results below 7,10 mm/s are acceptable. Measirung AV and VRMS values of three circulation pumps has shown that each of them are in an acceptable operating range. By calculating AV and VRMS values we get two curves for measuring spot CPV1-1H. In the graphic, first curve displays wave resulting from combining four max. AV values for each point while second one AV and VRMS amplitude shows „theorethical“ wave for measuring spot CPV1-1H.
Parallel keywords (Croatian)cirkulacijske crpke vibracije analiza i mjerenje vibracija
Resource typetext
Access conditionOpen access
Terms of usehttp://rightsstatements.org/vocab/InC/1.0/
Notediplomski rad
URN:NBNhttps://urn.nsk.hr/urn:nbn:hr:151:630105
CommitterLjiljana Vučković Vizentaner