master's thesis
The impact of RPM and shvitter of fan blades on vertical air distribution AGP 500 EN

Tadija Babić (2015)
Josip Juraj Strossmayer University of Osijek
Faculty of agriculture
DEPARTMENT FOR MECHANIZATION IN AGRICULTURE
Metadata
TitleUtjecaj broja okretaja i položaja lopatica aksijalnog ventilatora na vertikalnu raspodjelu zračne struje kod raspršivača AGP 500 EN
AuthorTadija Babić
Mentor(s)Đuro Banaj (thesis advisor)
Abstract
U praktikumu za mehanizaciju na Poljoprivrednom fakultetu u Osijeku obavljeno je utvrđivanje vertikalne raspodijele zračne struje raspršivača tvrtke Agromehanika oznake AGP 500 EN. Utvrđivanje je obavljeno pomoću meteorološke postaje postavljene na vertikalni sustav za pomicanje po visini. Ispitivanje raspršivača se obavljalo tako da je broj okretaja vratila traktora postavljeno na 180 o/min. Aksijalni ventilator promjera 825 mm kojeg posjeduje navedeni raspršivač ima pet lopatica koje se mogu postaviti u pet različitih zakošenja. Mjerenje se obavljalo sa četiri ponavljanja te se od tih vrijednosti uzela aritmetička sredina brzine strujanja zraka, te se izračunala standardna devijacija i koeficijent varijacije.
Keywordsmistblower AGP 500 EN vertical air distribution axial fan
Parallel title (English)The impact of RPM and shvitter of fan blades on vertical air distribution AGP 500 EN
Committee MembersPetar Lukač
Dražen Horvat
GranterJosip Juraj Strossmayer University of Osijek
Faculty of agriculture
Lower level organizational unitsDEPARTMENT FOR MECHANIZATION IN AGRICULTURE
PlaceOsijek
StateCroatia
Scientific field, discipline, subdisciplineBIOTECHNICAL SCIENCES
Agronomy
Agricultural Engineering and Technology
Study programme typeuniversity
Study levelgraduate
Study programmeMechanization
Academic title abbreviationmag. ing. agr.
Genremaster's thesis
Language Croatian
Defense date2015-09-29
Parallel abstract (English)
The workshop for machinery at Faculty of Agriculture conducted to determine the vertical distribution of air flow spray company Agromehanika AGP 500 EN labels. The determination is carried out using meteorological station installed on the vertical displacement system height. Testing spray was done so that the speed of the shaft of the tractor is set to 180 r / min. Axial fan diameter of 825 mm, which has given the mistblower has five blades that can be set in five different Mitre. The measurement was carried out with four repetitions and the value of these took the average value of air velocity and calculate the standard deviation and coefficient of variation
Parallel keywords (Croatian)raspršivač AGP 500 EN vertikalna raspodjela zraka aksijalni ventilator
Resource typetext
Access conditionOpen access
Terms of usehttp://rightsstatements.org/vocab/InC/1.0/
Notediplomski rad
URN:NBNhttps://urn.nsk.hr/urn:nbn:hr:151:067761
CommitterLjiljana Vučković Vizentaner